== Keysight B150xA Series Easy Test Navigator Software 1.2.3.0 Release Notes == == CORRESPONDING FIRMWARE REVISION == This revision of software works with the following firmware. - B150xA Series: A.06.00 or later == IMPROVEMENTS == - [9533] [Datasheet] Setup parameter adjusment is to be fed back into test condition input field. - [9547] [Gate Charge] IGBT Qg curve fitting is to be refined for case of negative Vge(off). - [9551] [Power Loss] Should read measurement data according to the name instead of the order. - [9553] [IV] Catch and report an unhandled exception in the thread of UI. - [9597] [Power Loss] Relaxation of extraction constraints for Rg == FIXED DEFECTS == - [9542] [Graph] Trace edge point in graph is to be rounded. - [9549] [Datasheet] The label of trace may be placed outside the frame of graph. - [9552] [IV] When the oscilloscope view has no data, mouse dragging with CTRL key pressing causes crash. - [9555] [Device Capacitance] Drain bias input may be disabled even in case of drain bias connection. - [9573] [Datasheet] In case of B1506AH21, IGES(-) for IGBT is not prepared. - [9575] [Datasheet] File filter for importing device symbol image is to be added. - [9581] [IV] Compensation of voltage drop for gate/drain resistance is not applied. - [9587] [Gate Charge] Modal calibraiton dialog can go behind of main window and lose operability. - [9589] [Datasheet] In case of component test, same connection instruction is always shown for thermo-trigger. - [9598] [Common] The first measurement after fixture resetting may be aborted unexpectedly. - [9599] [Gate Charge] SMU over-range isn't considered in parasitic capacitance correction. - [9606] [Gate Charge] Current load adjustment for Id(on) of 20A may fail in case of B1506AH21 (HCSMU). - [9612] [IV] Nomenclature for MOSFET is used for IGBT for step parameter name. - [9613] [Gate Charge] Extraction of Qg(on), Qg(th) and Qgs are to be updated for derived Qg. - [9616] [Datasheet] Graph of the positive log scale with the minus value can't be printed in XPS. - [9620] [Datasheet] Memory usage may increase for successive opening of ETN DS file. - [9630] [B1506AH71/H51] UHCU failure is indicated as MCSMU failure until performing Self Test. - [9632] [Power Loss] Null Reference Exception may occur after editing NaN Value. == REVISION HISTORY == New Features: - Oscilloscope View in I/V Measurement - Component Test in Datasheet Characterization - IGBT support in Power Loss Calculation - Output Capacitance Loss in Power Loss Calculation - [9512] [Datasheet] Saving in text format is to be supported. Improvements: - [9456] [Device Capacitance] Immittance data component displayed on graph is to be saved in data file. - [9457] [IV] RGS for graph data is to be supported. - [9469] [Graph] Data and scale setting are to be saved in setup file. - [9482] [Graph] Polarity of end points are to be kept for changing with mouse wheel operation. - [9483] [Graph] Support of simple operation for changing graph scale using mouse. - [9497] [Datasheet] Alias for data name in graph trace label is to be supported for appropriate expression. - [9503] [Gate Charge] S2 of derived JESD24-2 is to be identical to S2 of High Current JESD24-2. - [9505] [Gate Charge] S1 of derived JESD24-2 is to be identical to S1 of High Voltage JESD24-2. - [9507] [IV] Default aperture and step time for staircase sweep is to be extended. - [9514] [Datasheet] Limitation to min./max. range for parameters by related maximum rating is to be supported. - [9522] [Power Loss] Default sweep settings are to be updated to practical settings. - [9530] [Datasheet] Power compliance is to be applied in MOSFET > VDS-VGS for B1506AH21. - [9531] [Datasheet] Improvement in scrolling by scroll button. - [9536] [Common] Default input value options for numeric input field. - [9541] [Datasheet] Each measurement data is not to be saved in corresponding measurement DataStore in case of Datasheet execution. Fixed Defects: - [9454] [Datasheet] Maximum ratings are not applied to duplicated measurement items. - [9459] [Graph] Domain marker shift amount by rotary knob is not propotional to domain scale. - [9463] [Common] Path for save setup operation is to be nullified by opening data file. - [9484] [PowerLoss] Calculation of Irms is not the root mean square of drain current. - [9486] [PowerLoss] Inconsistent combination of Id/Ic, Irms and D can be set. - [9495] [Common] Input parameter values will be rounded inconsistently. - [9515] [PowerLoss] Calculation result of Conduction Loss is incorrect if Id/Ic or D is specified as a sweep parameter. New Features: - Initial release for B1506A and B1507A